The DVLS PetroReporter is a universal software tool that automates data processing and reporting of petroleum samples ranging from gases up to and including crude oil for DHA, Simdist and Gas Calculation applications. New feature is the EN14103 application to verify the ester content in FAME.

REPORTING FOR DHA, SIMDIST AND GAS CALCULATION

After data processing PetroReporter creates the required DHA, SimDist, Gas Calculation and FAME reports. PetroReporter is a universal software tool that allows refinery labs, independant labs and chemical plants to use one software package to process and report all petroleum samples. 

APPLICATION RANGE OF PETROREPORTER

  • ASTM, DIN, EN, IP, ISO applications for Simulated Distillation (SimDist)
  • ASTM D5134, D6729, D6730 & D6733 applications for Detailed Hydrocarbon Analysis (DHA)
  • ASTM, DIN, EN, GPA and ISO gas calculation modules.
  • EN14103-2012 and draft EN14103-2014 methods for verifying ester content in Fatty Acid Methyl Esters (FAME)

CONFIGURE YOUR GC WITH A DEDICATED DHA OR SIMDIST KIT

Da Vinci Laboratory Solutions offers several kits dedicated to a DHA and/or SimDist test method that includes the required GC column and calibration & validation samples. Combine the kits with PetroReporter to automate data processing and reporting of the petroleum samples. You can configure your gas chromatograph with one of the dedicated kits:

  • SimDist Kits that comply with an ASTM, DIN, EN or ISO method for simulated distillation:
    • ASTM D2887, D3710, D5442, D6352, D7096, D7169, D7213, D7500
    • IP 406, IP 480, IP 507, IP 545
    • ISO 3924
    • DIN 51.435, DIN 51.581
    • EN 15199-1, EN 15199-2, EN 15199-3
  • DHA Kits that comply with ASTM D5134, D6729, D6730 or D6733 for detailed hydrocarbon analysis 
DVLS PetroReporter DHA DVLS PetroReporter SimDist DVLS PetroReporter Gas
DHA Report SimDist Report  Gas Calculation Report

DVLS PETROREPORTER BENEFITS:

  • One universal tool for DHA, SimDist, Gas Calculation and FAME applications
  • A compatibility with multiple data platforms such as Agilent EZChrom Elite, OpenLab EZChrom, Agilent ChemStation, OpenLab ChemStation, DataApex Clarity, Perkin Elmer TotalChrom, Scion Compass, Thermo Atlas, Thermo Chromeleon  
  • A stand-alone or network configuration that allows you to process the analysis data from any PC workstation
  • A wide range of report options to register the individual components, physical properties or values
  • Predefined settings per sample type, component tables and formulas to optimize the identification of the petroleum samples
  • User-friendly editors to customize the settings on-screen, just drag and drop the peaks in the on-screen chromatogram to adjust the identification